Antiferro magnetic calculations require a somewhat more tricky setup, because at present VASP does not check whether the initial magnetic moments break the symmetry. The simplest way to break the symmetry is by using two different species. A POSCAR file for AF Cr would be:
Cr: AF 2.80000 1.00000 .00000 .00000 .00000 1.00000 .00000 .00000 .00000 1.00000 1 1 Kartesisch .00000 .00000 .00000 .50000 .50000 .50000and the INCAR file should have a line
MAGMOM = 1 -1The POTCAR file should of course also contain the Cr PP twice. (in one of the next VASP releases this problem will be fixed, i.e. VASP will check which symmetry opertation have to be removed