Next: 9.6.3 Accurate bulk relaxations
Up: 9.6 Volume vs. energy
Previous: 9.6.1 How to calculate
The general message is: whenever
possible avoid volume relaxation with the default energy cutoff.
Either increase the basis set by setting ENCUT manually in
the INCAR file,
or use the method suggested below, which avoids volume relaxations at all.
If volume relaxation are the only possible and feasible
option please use the following step by step procedure (which minimize
errors to a minimum):
- Relax from starting structure (ISMEAR should be 0 or 1, see
section 7.33).
- Start a second relaxation from previous CONTCAR file (re-relaxation).
- As a final step perform one more energy calculation with the
tetrahedron method
switched on (i.e. ISMEAR=-5), to get very accurate and unambiguous energies
(no relaxation for the final run). The final calculation
should be done with PREC=High, to get very accurate energies.
A few things should be remarked here:
Never take the energy obtained at the end of a relaxation run, if you allow
for cell shape relaxations (because the final basis set might not be isotropic).
The relaxation will give a structure
which is correct to first order, the final errors in step 3 is of second
order (with respect to the structural errors). If you take the
energy directly from the relaxation run errors are usually significantly larger.
Another important point is that the most accurate results
for the relaxation will be obtained
if the starting cell parameters are very close to the final
cell parameters. If different runs yield different results, then
the run which started from the configuration which was closest
to the relaxed structure, is probably most reliable.
We strongly recommend to do any volume (and to lesser extend
cell shape) relaxation with an
increased basis set. ENCUT=1.3
default cutoff is reasonable
accurate in most cases. If the default cutoff is used
for the relaxation the Pulay stress corrections outlined below
should be used (but we can not really recommend this technique).
Also mind, that one is often saved by the fact that first
order structural errors will results only in a second order
error in the energy (at least if the procedure outlined above is
used).
Finally we want to point out that there is a way to correct
the leading errors due to the Pulay stress. Evaluate the Pulay stress
along the guidelines given above and add an input-line to the INCAR file which
reads
From no on all STRESS output of VASP is corrected by simply subtracting PSTRESS.
In addition, all volume relaxations will take PSTRESS into account
(see sec. 7.22).
Next: 9.6.3 Accurate bulk relaxations
Up: 9.6 Volume vs. energy
Previous: 9.6.1 How to calculate
MASTER USER VASP
Mon Mar 29 10:38:29 MEST 1999